Invoke-NSUnsetStreamIdentifier
SYNOPSIS
Clears one or more NetScaler streamidentifier resource properties.
SYNTAX
Invoke-NSUnsetStreamIdentifier [-Name] <String> [-AcceptanceThreshold] [-AppFlowLog] [-BreachThreshold]
[-Interval] [-Log] [-LoginTerval] [-Loglimit] [-MaxTransActionThreshold] [-MinTransActionThreshold]
[-Samplecount] [-SelectorName] [-SNMPTrap] [-Sort] [-Trackackonlypackets] [-TracktransActionS]
[-Session <PSObject>] [-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-PassThru] [-WhatIf]
[-Confirm] [<CommonParameters>]
DESCRIPTION
Configuration for identifier resource.
EXAMPLES
EXAMPLE 1
EXAMPLE 2
PARAMETERS
-Name
The name of stream identifier.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: 1
Default value: None
Accept pipeline input: True (ByPropertyName)
Accept wildcard characters: False
-AcceptanceThreshold
Non-Breaching transactions to Total transactions threshold expressed in percent. Maximum of 6 decimal places is supported. Default value: 0.000000 Maximum length = 10
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-AppFlowLog
Enable/disable Appflow logging for stream identifier. Default value: DISABLED Possible values = ENABLED, DISABLED
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-BreachThreshold
Breaching transactions threshold calculated over interval. Default value: 0
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Interval
Number of minutes of data to use when calculating session statistics (number of requests, bandwidth, and response times). The interval is a moving window that keeps the most recently collected data. Older data is discarded at regular intervals. Default value: 1 Minimum value = 1 Maximum value = 10080
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Log
Location where objects collected on the identifier will be logged. Default value: NONE Possible values = SYSLOG, NONE
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-LoginTerval
Time interval in minutes for logging the collected objects. Log interval should be greater than or equal to the inteval of the stream identifier. Default value: 5 Minimum value = 1 Maximum value = 10080
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Loglimit
Maximum number of objects to be logged in the log interval. Default value: 100 Minimum value = 1 Maximum value = 1000
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-MaxTransActionThreshold
Maximum per transcation value of metric. Metric to be tracked is specified by tracktransactions attribute. Default value: 0
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-MinTransActionThreshold
Minimum per transcation value of metric. Metric to be tracked is specified by tracktransactions attribute. Default value: 0
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Samplecount
Size of the sample from which to select a request for evaluation. The smaller the sample count, the more accurate is the statistical data. To evaluate all requests, set the sample count to 1. However, such a low setting can result in excessive consumption of memory and processing resources. Default value: 1 Minimum value = 1 Maximum value = 65535
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-SelectorName
Name of the selector to use with the stream identifier. Minimum length = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-SNMPTrap
Enable/disable SNMP trap for stream identifier. Default value: DISABLED Possible values = ENABLED, DISABLED
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Sort
Sort stored records by the specified statistics column, in descending order. Performed during data collection, the sorting enables real-time data evaluation through Citrix ADC policies (for example, compression and caching policies) that use functions such as IS_TOP(n). Default value: REQUESTS Possible values = REQUESTS, CONNECTIONS, RESPTIME, BANDWIDTH, RESPTIME_BREACHES, NONE
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Trackackonlypackets
Track ack only packets as well. This setting is applicable only when packet rate limiting is being used. Default value: DISABLED Possible values = ENABLED, DISABLED
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-TracktransActionS
Track transactions exceeding configured threshold. Transaction tracking can be enabled for following metric: ResponseTime. By default transaction tracking is disabled. Default value: NONE Possible values = RESPTIME, NONE
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Session
The NetScaler session. If omitted, the current default session is used.
Type: PSObject
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False
-IgnoreNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ReturnNullOnNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ThrowOnWarning
Treats NITRO warning responses as terminating errors.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-PassThru
Returns the updated resource after the operation completes.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSCustomObject
NOTES
Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.