Invoke-NSUnsetSNMPMib
SYNOPSIS
Clears one or more NetScaler snmpmib resource properties.
SYNTAX
Invoke-NSUnsetSNMPMib [-Ownernode] <Int32> [-Contact] [-CustomId] [-Location] [-Name] [-Session <PSObject>]
[-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-PassThru] [-WhatIf] [-Confirm]
[<CommonParameters>]
DESCRIPTION
Configuration for SNMP mib resource.
EXAMPLES
EXAMPLE 1
EXAMPLE 2
PARAMETERS
-Ownernode
ID of the cluster node for which we are setting the mib. This is a mandatory argument to set snmp mib on CLIP. Default value: -1 Minimum value = 0 Maximum value = 31
Type: Int32
Parameter Sets: (All)
Aliases:
Required: True
Position: 1
Default value: 0
Accept pipeline input: True (ByPropertyName)
Accept wildcard characters: False
-Contact
Name of the administrator for this Citrix ADC. Along with the name, you can include information on how to contact this person, such as a phone number or an email address. Can consist of 1 to 127 characters that include uppercase and lowercase letters, numbers, and the hyphen (-), period (.) pound (#), space ( ), at sign (@), equals (=), colon (:), and underscore (_) characters. The following requirement applies only to the Citrix ADC CLI: If the information includes one or more spaces, enclose it in double or single quotation marks (for example, "my contact" or 'my contact'). Default value: "WebMaster (default)" Minimum length = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-CustomId
Custom identification number for the Citrix ADC. Can consist of 1 to 127 characters that include uppercase and lowercase letters, numbers, and the hyphen (-), period (.) pound (#), space ( ), at sign (@), equals (=), colon (:), and underscore (_) characters. You should choose a custom identification that helps identify the Citrix ADC appliance. The following requirement applies only to the Citrix ADC CLI: If the ID includes one or more spaces, enclose it in double or single quotation marks (for example, "my ID" or 'my ID'). Default value: "Default" Minimum length = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Location
Physical location of the Citrix ADC. For example, you can specify building name, lab number, and rack number. Can consist of 1 to 127 characters that include uppercase and lowercase letters, numbers, and the hyphen (-), period (.) pound (#), space ( ), at sign (@), equals (=), colon (:), and underscore (_) characters. The following requirement applies only to the Citrix ADC CLI: If the location includes one or more spaces, enclose it in double or single quotation marks (for example, "my location" or 'my location'). Default value: "POP (default)" Minimum length = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Name
Name for this Citrix ADC. Can consist of 1 to 127 characters that include uppercase and lowercase letters, numbers, and the hyphen (-), period (.) pound (#), space ( ), at sign (@), equals (=), colon (:), and underscore (_) characters. You should choose a name that helps identify the Citrix ADC appliance. The following requirement applies only to the Citrix ADC CLI: If the name includes one or more spaces, enclose it in double or single quotation marks (for example, "my name" or 'my name'). Default value: "NetScaler" Minimum length = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Session
The NetScaler session. If omitted, the current default session is used.
Type: PSObject
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False
-IgnoreNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ReturnNullOnNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ThrowOnWarning
Treats NITRO warning responses as terminating errors.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-PassThru
Returns the updated resource after the operation completes.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSCustomObject
NOTES
Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.