Invoke-NSAddTimerAutoscalePolicyBinding
SYNOPSIS
Creates a NetScaler nstimer_autoscalepolicy_binding resource.
SYNTAX
Invoke-NSAddTimerAutoscalePolicyBinding [-GotoPriorityExpression <String>] [-Name] <String>
-PolicyName <String> -Priority <Int32> [-Samplesize <Int32>] [-Threshold <Int32>] [-VServer <String>]
[-Session <PSObject>] [-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-PassThru] [-WhatIf]
[-Confirm] [<CommonParameters>]
DESCRIPTION
Binding object showing the autoscalepolicy that can be bound to nstimer.
EXAMPLES
EXAMPLE 1
EXAMPLE 2
PARAMETERS
-GotoPriorityExpression
Expression specifying the priority of the next policy which will get evaluated if the current policy rule evaluates to TRUE.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Name
Timer name. Minimum length = 1
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: 1
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-PolicyName
The timer policy associated with the timer.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Priority
Specifies the priority of the timer policy.
Type: Int32
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Samplesize
Denotes the sample size. Sample size value of 'x' means that previous '(x - 1)' policy's rule evaluation results and the current evaluation result are present with the binding. For example, sample size of 10 means that there is a state of previous 9 policy evaluation results and also the current policy evaluation result. Default value: 3 Minimum value = 1 Maximum value = 32
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Threshold
Denotes the threshold. If the rule of the policy in the binding relation evaluates 'threshold size' number of times in 'sample size' to true, then the corresponding action is taken. Its value needs to be less than or equal to the sample size value. Default value: 3 Minimum value = 1 Maximum value = 32
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-VServer
Name of the vserver which provides the context for the rule in timer policy. When not specified it is treated as a Global Default context.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Session
The NetScaler session. If omitted, the current default session is used.
Type: PSObject
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False
-IgnoreNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ReturnNullOnNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ThrowOnWarning
Treats NITRO warning responses as terminating errors.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-PassThru
Returns the updated resource after the operation completes.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSCustomObject
NOTES
Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.