Skip to content

Invoke-NSUnsetSubscriberparam

SYNOPSIS

Clears one or more NetScaler subscriberparam resource properties.

SYNTAX

Invoke-NSUnsetSubscriberparam [-IdleAction] [-Idlettl] [-InterfaceType] [-KeyType] [[-Session] <PSObject>]
 [-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-PassThru] [-WhatIf] [-Confirm]
 [<CommonParameters>]

DESCRIPTION

Configuration for Subscriber Params resource.

EXAMPLES

EXAMPLE 1

Invoke-NSUnsetSubscriberparam -IdleAction ccrTerminate -PassThru

EXAMPLE 2

Invoke-NSUnsetSubscriberparam -IdleAction ccrTerminate -WhatIf

PARAMETERS

-IdleAction

q!Once idleTTL exprires on a subscriber session, Citrix ADC will take an idle action on that session. idleAction could be chosen from one of these ==> 1. ccrTerminate: (default) send CCR-T to inform PCRF about session termination and delete the session. 2. delete: Just delete the subscriber session without informing PCRF. 3. ccrUpdate: Do not delete the session and instead send a CCR-U to PCRF requesting for an updated session. !. Default value: ccrTerminate Possible values = ccrTerminate, delete, ccrUpdate

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-Idlettl

q!Idle Timeout, in seconds, after which Citrix ADC will take an idleAction on a subscriber session (refer to 'idleAction' arguement in 'set subscriber param' for more details on idleAction). Any data-plane or control plane activity updates the idleTimeout on subscriber session. idleAction could be to 'just delete the session' or 'delete and CCR-T' (if PCRF is configured) or 'do not delete but send a CCR-U'. Zero value disables the idle timeout. !. Default value: 0 Minimum value = 0 Maximum value = 172800

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-InterfaceType

Subscriber Interface refers to Citrix ADC interaction with control plane protocols, RADIUS and GX. Types of subscriber interface: NONE, RadiusOnly, RadiusAndGx, GxOnly. NONE: Only static subscribers can be configured. RadiusOnly: GX interface is absent. Subscriber information is obtained through RADIUS Accounting messages. RadiusAndGx: Subscriber ID obtained through RADIUS Accounting is used to query PCRF. Subscriber information is obtained from both RADIUS and PCRF. GxOnly: RADIUS interface is absent. Subscriber information is queried using Subscriber IP or IP+VLAN. Default value: None Possible values = None, RadiusOnly, RadiusAndGx, GxOnly

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-KeyType

Type of subscriber key type IP or IPANDVLAN. IPANDVLAN option can be used only when the interfaceType is set to gxOnly. Changing the lookup method should result to the subscriber session database being flushed. Default value: IP Possible values = IP, IPANDVLAN

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-Session

The NetScaler session. If omitted, the current default session is used.

Type: PSObject
Parameter Sets: (All)
Aliases:

Required: False
Position: 1
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False

-IgnoreNotFound

Returns null instead of throwing for known NITRO not-found responses.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-ReturnNullOnNotFound

Returns null instead of throwing for known NITRO not-found responses.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-ThrowOnWarning

Treats NITRO warning responses as terminating errors.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-PassThru

Returns the updated resource after the operation completes.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

OUTPUTS

System.Management.Automation.PSCustomObject

NOTES

Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.