Invoke-NSUpdateSmppparam
SYNOPSIS
Updates a NetScaler smppparam resource.
SYNTAX
Invoke-NSUpdateSmppparam [[-Addrnpi] <Int32>] [[-Addrrange] <String>] [[-Addrton] <Int32>]
[[-ClientMode] <String>] [[-Msgqueue] <String>] [[-Msgqueuesize] <Int32>] [[-Session] <PSObject>]
[-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-PassThru] [-WhatIf] [-Confirm]
[<CommonParameters>]
DESCRIPTION
Configuration for SMPP configuration parameters resource.
EXAMPLES
EXAMPLE 1
EXAMPLE 2
PARAMETERS
-Addrnpi
Numbering Plan Indicator, such as landline, data, or WAP client, used in the ESME address sent in the bind request. Default value: 0 Minimum value = 0 Maximum value = 256
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: 1
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Addrrange
Set of SME addresses, sent in the bind request, serviced by the ESME. Default value: "\\d*"
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 2
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Addrton
Type of Number, such as an international number or a national number, used in the ESME address sent in the bind request. Default value: 0 Minimum value = 0 Maximum value = 256
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: 3
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-ClientMode
Mode in which the client binds to the ADC. Applicable settings function as follows: * TRANSCEIVER - Client can send and receive messages to and from the message center. * TRANSMITTERONLY - Client can only send messages. * RECEIVERONLY - Client can only receive messages. Default value: TRANSCEIVER Possible values = TRANSCEIVER, TRANSMITTERONLY, RECEIVERONLY
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 4
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Msgqueue
Queue SMPP messages if a client that is capable of receiving the destination address messages is not available. Default value: OFF Possible values = ON, OFF
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 5
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Msgqueuesize
Maximum number of SMPP messages that can be queued. After the limit is reached, the Citrix ADC sends a deliver_sm_resp PDU, with an appropriate error message, to the message center. Default value: 10000
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: 6
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Session
The NetScaler session. If omitted, the current default session is used.
Type: PSObject
Parameter Sets: (All)
Aliases:
Required: False
Position: 7
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False
-IgnoreNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ReturnNullOnNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ThrowOnWarning
Treats NITRO warning responses as terminating errors.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-PassThru
Returns the updated resource after the operation completes.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSCustomObject
NOTES
Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.