Skip to content

Invoke-NSUnsetSmppparam

SYNOPSIS

Clears one or more NetScaler smppparam resource properties.

SYNTAX

Invoke-NSUnsetSmppparam [-Addrnpi] [-Addrrange] [-Addrton] [-ClientMode] [-Msgqueue] [-Msgqueuesize]
 [[-Session] <PSObject>] [-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-PassThru] [-WhatIf]
 [-Confirm] [<CommonParameters>]

DESCRIPTION

Configuration for SMPP configuration parameters resource.

EXAMPLES

EXAMPLE 1

Invoke-NSUnsetSmppparam -Addrnpi  -PassThru

EXAMPLE 2

Invoke-NSUnsetSmppparam -Addrnpi  -WhatIf

PARAMETERS

-Addrnpi

Numbering Plan Indicator, such as landline, data, or WAP client, used in the ESME address sent in the bind request. Default value: 0 Minimum value = 0 Maximum value = 256

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-Addrrange

Set of SME addresses, sent in the bind request, serviced by the ESME. Default value: "\\d*"

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-Addrton

Type of Number, such as an international number or a national number, used in the ESME address sent in the bind request. Default value: 0 Minimum value = 0 Maximum value = 256

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-ClientMode

Mode in which the client binds to the ADC. Applicable settings function as follows: * TRANSCEIVER - Client can send and receive messages to and from the message center. * TRANSMITTERONLY - Client can only send messages. * RECEIVERONLY - Client can only receive messages. Default value: TRANSCEIVER Possible values = TRANSCEIVER, TRANSMITTERONLY, RECEIVERONLY

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-Msgqueue

Queue SMPP messages if a client that is capable of receiving the destination address messages is not available. Default value: OFF Possible values = ON, OFF

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-Msgqueuesize

Maximum number of SMPP messages that can be queued. After the limit is reached, the Citrix ADC sends a deliver_sm_resp PDU, with an appropriate error message, to the message center. Default value: 10000

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-Session

The NetScaler session. If omitted, the current default session is used.

Type: PSObject
Parameter Sets: (All)
Aliases:

Required: False
Position: 1
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False

-IgnoreNotFound

Returns null instead of throwing for known NITRO not-found responses.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-ReturnNullOnNotFound

Returns null instead of throwing for known NITRO not-found responses.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-ThrowOnWarning

Treats NITRO warning responses as terminating errors.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-PassThru

Returns the updated resource after the operation completes.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

OUTPUTS

System.Management.Automation.PSCustomObject

NOTES

Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.