Invoke-NSAddQUICProfile

SYNOPSIS

Creates a NetScaler quicprofile resource.

SYNTAX

Invoke-NSAddQUICProfile [-Ackdelayexponent <Int32>] [-ActiveConnectionIdlimit <Int32>]
 [-ActiveConnectionMigration <String>] [-Congestionctrlalgorithm <String>] [-InitialMaxData <Int32>]
 [-InitialMaxStreamDataBidiLocal <Int32>] [-InitialMaxStreamDataBidiremote <Int32>]
 [-InitialMaxStreamDataUni <Int32>] [-InitialMaxStreamsbidi <Int32>] [-InitialMaxStreamsuni <Int32>]
 [-MaxAckdelay <Int32>] [-MaxIdleTimeout <Int32>] [-MaxUDPDataGramsperburst <Int32>]
 [-MaxUDPPayloadsize <Int32>] [-Name] <String> [-NewtokenvalidiTypeRiod <Int32>]
 [-RetrytokenvalidiTypeRiod <Int32>] [-Statelessaddressvalidation <String>] [-Session <PSObject>]
 [-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-PassThru] [-WhatIf] [-Confirm]
 [<CommonParameters>]

DESCRIPTION

Configuration for QUIC profile resource.

EXAMPLES

EXAMPLE 1

Invoke-NSAddQUICProfile -Name 'example' -PassThru

EXAMPLE 2

Invoke-NSAddQUICProfile -Name 'example' -WhatIf

PARAMETERS

-Ackdelayexponent

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, indicating an exponent that the remote QUIC endpoint should use, to decode the ACK Delay field in QUIC ACK frames sent by the Citrix ADC. Default value: 3 Minimum value = 0 Maximum value = 20

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-ActiveConnectionIdlimit

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the maximum number of QUIC connection IDs from the remote QUIC endpoint, that the Citrix ADC is willing to store. Default value: 3 Minimum value = 2 Maximum value = 8

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-ActiveConnectionMigration

Specify whether the Citrix ADC should allow the remote QUIC endpoint to perform active QUIC connection migration. Default value: ENABLED Possible values = ENABLED, DISABLED

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Congestionctrlalgorithm

Specify the congestion control algorithm to be used for QUIC connections. The default congestion control algorithm is CUBIC. Default value: Default Possible values = Default, NewReno, CUBIC, BBR

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-InitialMaxData

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the initial value, in bytes, for the maximum amount of data that can be sent on a QUIC connection. Default value: 1048576 Minimum value = 8192 Maximum value = 67108864

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-InitialMaxStreamDataBidiLocal

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the initial flow control limit, in bytes, for bidirectional QUIC streams initiated by the Citrix ADC. Default value: 262144 Minimum value = 8192 Maximum value = 8388608

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-InitialMaxStreamDataBidiremote

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the initial flow control limit, in bytes, for bidirectional QUIC streams initiated by the remote QUIC endpoint. Default value: 262144 Minimum value = 8192 Maximum value = 8388608

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-InitialMaxStreamDataUni

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the initial flow control limit, in bytes, for unidirectional streams initiated by the remote QUIC endpoint. Default value: 262144 Minimum value = 8192 Maximum value = 8388608

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-InitialMaxStreamsbidi

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the initial maximum number of bidirectional streams the remote QUIC endpoint may initiate. Default value: 100 Minimum value = 1 Maximum value = 500

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-InitialMaxStreamsuni

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the initial maximum number of unidirectional streams the remote QUIC endpoint may initiate. Default value: 10 Minimum value = 1 Maximum value = 500

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-MaxAckdelay

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the maximum amount of time, in milliseconds, by which the Citrix ADC will delay sending acknowledgments. Default value: 20 Minimum value = 10 Maximum value = 2000

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-MaxIdleTimeout

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the maximum idle timeout, in seconds, for a QUIC connection. A QUIC connection will be silently discarded by the Citrix ADC if it remains idle for longer than the minimum of the idle timeout values advertised by the Citrix ADC and the remote QUIC endpoint, and three times the current Probe Timeout (PTO). Default value: 180 Minimum value = 1 Maximum value = 3600

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-MaxUDPDataGramsperburst

An integer value, specifying the maximum number of UDP datagrams that can be transmitted by the Citrix ADC in a single transmission burst on a QUIC connection. Default value: 8 Minimum value = 1 Maximum value = 256

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-MaxUDPPayloadsize

An integer value advertised by the Citrix ADC to the remote QUIC endpoint, specifying the size of the largest UDP datagram payload, in bytes, that the Citrix ADC is willing to receive on a QUIC connection. Default value: 1472 Minimum value = 1252 Maximum value = 9188

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-Name

Name for the QUIC profile. Must begin with an ASCII alphanumeric or underscore (_) character, and must contain only ASCII alphanumeric, underscore, hash (#), period (.), space, colon (:), at (@),equals sign (=), and hyphen (-) characters. Cannot be changed after the profile is created. Minimum length = 1 Maximum length = 256

Type: String
Parameter Sets: (All)
Aliases:

Required: True
Position: 1
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-NewtokenvalidiTypeRiod

An integer value, specifying the validity period, in seconds, of address validation tokens issued through QUIC NEW_TOKEN frames sent by the Citrix ADC. Default value: 300 Minimum value = 1 Maximum value = 3600

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-RetrytokenvalidiTypeRiod

An integer value, specifying the validity period, in seconds, of address validation tokens issued through QUIC Retry packets sent by the Citrix ADC. Default value: 10 Minimum value = 1 Maximum value = 120

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-Statelessaddressvalidation

Specify whether the Citrix ADC should perform stateless address validation for QUIC clients, by sending tokens in QUIC Retry packets during QUIC connection establishment, and by sending tokens in QUIC NEW_TOKEN frames after QUIC connection establishment. Default value: ENABLED Possible values = ENABLED, DISABLED

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Session

The NetScaler session. If omitted, the current default session is used.

Type: PSObject
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False

-IgnoreNotFound

Returns null instead of throwing for known NITRO not-found responses.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-ReturnNullOnNotFound

Returns null instead of throwing for known NITRO not-found responses.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-ThrowOnWarning

Treats NITRO warning responses as terminating errors.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-PassThru

Returns the updated resource after the operation completes.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

OUTPUTS

System.Management.Automation.PSCustomObject

NOTES

Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.