Invoke-NSDeleteNetProfileSrcPortSetBinding
SYNOPSIS
Removes a NetScaler netprofile_srcportset_binding resource.
SYNTAX
Invoke-NSDeleteNetProfileSrcPortSetBinding [-Name] <String> [-SrcPortRange <String>] [-Session <PSObject>]
[-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-WhatIf] [-Confirm] [<CommonParameters>]
DESCRIPTION
Binding object showing the srcportset that can be bound to netprofile.
EXAMPLES
EXAMPLE 1
EXAMPLE 2
Invoke-NSGetNetProfileSrcPortSetBinding -Name 'netprofile_srcportset_binding_example' | Invoke-NSDeleteNetProfileSrcPortSetBinding -Confirm:$false
PARAMETERS
-Name
Name of the netprofile to which to bind port ranges. Minimum length = 1
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: 1
Default value: None
Accept pipeline input: True (ByPropertyName)
Accept wildcard characters: False
-SrcPortRange
When the source port range is configured and associated with the netprofile bound to a service group, Citrix ADC will choose a port from the range configured for connection establishment at the backend servers. Minimum length = 1024 Maximum length = 65535
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Session
The NetScaler session. If omitted, the current default session is used.
Type: PSObject
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False
-IgnoreNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ReturnNullOnNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ThrowOnWarning
Treats NITRO warning responses as terminating errors.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSCustomObject
NOTES
Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.