Invoke-NSUnsetNscqaparam
SYNOPSIS
Clears one or more NetScaler nscqaparam resource properties.
SYNTAX
Invoke-NSUnsetNscqaparam [-Harqretxdelay] [-Lr1coeflist] [-Lr1probthresh] [-MinRttnet1] [-MinRttnet2]
[-MinRttnet3] [-Net1cclscale] [-Net1csqscale] [-Net1Label] [-Net1logcoef] [-Net2cclscale] [-Net2csqscale]
[-Net2Label] [-Net2logcoef] [-Net3cclscale] [-Net3csqscale] [-Net3Label] [-Net3logcoef]
[[-Session] <PSObject>] [-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-PassThru] [-WhatIf]
[-Confirm] [<CommonParameters>]
DESCRIPTION
Configuration for cqaparam resource.
EXAMPLES
EXAMPLE 1
EXAMPLE 2
PARAMETERS
-Harqretxdelay
HARQ retransmission delay (in ms). Default value: 0 Minimum value = 1 Maximum value = 64000
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Lr1coeflist
coefficients values for Label1.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Lr1probthresh
Probability threshold values for LR model to differentiate between NET1 and reset(NET2 and NET3). Default value: 0 Minimum value = 0 Maximum value = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-MinRttnet1
MIN RTT (in ms) for the first network. Default value: 0 Minimum value = 0 Maximum value = 6400
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-MinRttnet2
MIN RTT (in ms) for the second network. Default value: 0 Minimum value = 0 Maximum value = 6400
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-MinRttnet3
MIN RTT (in ms) for the third network. Default value: 0 Minimum value = 0 Maximum value = 6400
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net1cclscale
Three congestion level scores limits corresponding to None, Low, Medium.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net1csqscale
Three signal quality level scores limits corresponding to Excellent, Good, Fair.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net1Label
Name of the network label. Maximum length = 15
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net1logcoef
Connection quality ranking Log coefficients of network 1.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net2cclscale
Three congestion level scores limits corresponding to None, Low, Medium.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net2csqscale
Three signal quality level scores limits corresponding to Excellent, Good, Fair.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net2Label
Name of the network label 2. Maximum length = 15
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net2logcoef
Connnection quality ranking Log coefficients of network 2.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net3cclscale
Three congestion level scores limits corresponding to None, Low, Medium.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net3csqscale
Three signal quality level scores limits corresponding to Excellent, Good, Fair.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net3Label
Name of the network label 3. Maximum length = 15
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Net3logcoef
Connection quality ranking Log coefficients of network 3.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Session
The NetScaler session. If omitted, the current default session is used.
Type: PSObject
Parameter Sets: (All)
Aliases:
Required: False
Position: 1
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False
-IgnoreNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ReturnNullOnNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ThrowOnWarning
Treats NITRO warning responses as terminating errors.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-PassThru
Returns the updated resource after the operation completes.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSCustomObject
NOTES