Invoke-NSAddLSNSIPALGProfile
Module area: NetScalerToolkit
Synopsis
Generated command reference. Review the command syntax and parameter metadata before use.
Syntax
Invoke-NSAddLSNSIPALGProfile [-DataSessionidleTimeout <Int32>] [-Opencontactpinhole <String>] [-OpenRecordRoutepinhole <String>] [-Openregisterpinhole <String>] [-Openroutepinhole <String>] [-OpenviAPINhole <String>] [-RegistrationTimeout <Int32>] [-RPort <String>] -SIPAlgProfileName <String> [-SIPDstPortRange <String>] [-SIPSessionTimeout <Int32>] [-SIPSrcPortRange <String>] -SIPTransPortProtocol <String> [-Session <PSObject>] [-IgnoreNotFound <SwitchParameter>] [-ReturnNullOnNotFound <SwitchParameter>] [-ThrowOnWarning <SwitchParameter>] [-PassThru <SwitchParameter>]
Parameters
-Confirm
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False - Aliases:
cf
-DataSessionidleTimeout
- Type:
System.Int32 - Required:
False - Pipeline input:
False
-IgnoreNotFound
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-Opencontactpinhole
- Type:
System.String - Required:
False - Pipeline input:
False
-OpenRecordRoutepinhole
- Type:
System.String - Required:
False - Pipeline input:
False
-Openregisterpinhole
- Type:
System.String - Required:
False - Pipeline input:
False
-Openroutepinhole
- Type:
System.String - Required:
False - Pipeline input:
False
-OpenviAPINhole
- Type:
System.String - Required:
False - Pipeline input:
False
-PassThru
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-RegistrationTimeout
- Type:
System.Int32 - Required:
False - Pipeline input:
False
-ReturnNullOnNotFound
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-RPort
- Type:
System.String - Required:
False - Pipeline input:
False
-Session
- Type:
System.Management.Automation.PSObject - Required:
False - Pipeline input:
False
-SIPAlgProfileName
- Type:
System.String - Required:
True - Pipeline input:
False
-SIPDstPortRange
- Type:
System.String - Required:
False - Pipeline input:
False
-SIPSessionTimeout
- Type:
System.Int32 - Required:
False - Pipeline input:
False
-SIPSrcPortRange
- Type:
System.String - Required:
False - Pipeline input:
False
-SIPTransPortProtocol
- Type:
System.String - Required:
True - Pipeline input:
False
-ThrowOnWarning
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-WhatIf
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False - Aliases:
wi
Notes
This page was generated from exported PowerShell command metadata.