Skip to content

Invoke-NSAddLSNAppsAttributes

SYNOPSIS

Creates a NetScaler lsnappsattributes resource.

SYNTAX

Invoke-NSAddLSNAppsAttributes [-Name] <String> [-Port <String>] [-SessionTimeout <Int32>]
 -TransPortProtocol <String> [-Session <PSObject>] [-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning]
 [-PassThru] [-WhatIf] [-Confirm] [<CommonParameters>]

DESCRIPTION

Configuration for LSN Application Attributes resource.

EXAMPLES

EXAMPLE 1

Invoke-NSAddLSNAppsAttributes -Name 'example' -TransPortProtocol TCP -Port 80 -PassThru

EXAMPLE 2

Invoke-NSAddLSNAppsAttributes -Name 'example' -TransPortProtocol TCP -Port 80 -WhatIf

PARAMETERS

-Name

Name for the LSN Application Port ATTRIBUTES. Must begin with an ASCII alphanumeric or underscore (_) character, and must contain only ASCII alphanumeric, underscore, hash (#), period (.), space, colon (:), at (@), equals (=), and hyphen (-) characters. Cannot be changed after the LSN application profile is created. The following requirement applies only to the Citrix ADC CLI: If the name includes one or more spaces, enclose the name in double or single quotation marks (for example, "lsn application profile1" or 'lsn application profile1'). Minimum length = 1 Maximum length = 127

Type: String
Parameter Sets: (All)
Aliases:

Required: True
Position: 1
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Port

This is used for Displaying Port/Port range in CLI/Nitro.Lowport, Highport values are populated and used for displaying.Port numbers or range of port numbers to match against the destination port of the incoming packet from a subscriber. When the destination port is matched, the LSN application profile is applied for the LSN session. Separate a range of ports with a hyphen. For example, 40-90. Minimum length = 1

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-SessionTimeout

Timeout, in seconds, for an idle LSN session. If an LSN session is idle for a time that exceeds this value, the Citrix ADC removes the session.This timeout does not apply for a TCP LSN session when a FIN or RST message is received from either of the endpoints. Default value: 30 Minimum value = 5 Maximum value = 600

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-TransPortProtocol

Name of the protocol(TCP,UDP) for which the parameters of this LSN application port ATTRIBUTES applies. Possible values = TCP, UDP, ICMP

Type: String
Parameter Sets: (All)
Aliases:

Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Session

The NetScaler session. If omitted, the current default session is used.

Type: PSObject
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False

-IgnoreNotFound

Returns null instead of throwing for known NITRO not-found responses.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-ReturnNullOnNotFound

Returns null instead of throwing for known NITRO not-found responses.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-ThrowOnWarning

Treats NITRO warning responses as terminating errors.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-PassThru

Returns the updated resource after the operation completes.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

OUTPUTS

System.Management.Automation.PSCustomObject

NOTES

Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.