Invoke-NSAddLBWLM
SYNOPSIS
Creates a NetScaler lbwlm resource.
SYNTAX
Invoke-NSAddLBWLM [-Ipaddress <String>] [-KaTimeout <Int32>] -Lbuid <String> [-Port <Int32>]
[-WlmName] <String> [-Session <PSObject>] [-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning]
[-PassThru] [-WhatIf] [-Confirm] [<CommonParameters>]
DESCRIPTION
Configuration for web log manager resource.
EXAMPLES
EXAMPLE 1
EXAMPLE 2
PARAMETERS
-Ipaddress
The IP address of the WLM.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-KaTimeout
The idle time period after which Citrix ADC would probe the WLM. The value ranges from 1 to 1440 minutes. Default value: 2 Minimum value = 0 Maximum value = 1440
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Lbuid
The LBUID for the Load Balancer to communicate to the Work Load Manager.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Port
The port of the WLM. Range 1 - 65535 * in CLI is represented as 65535 in NITRO API
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-WlmName
The name of the Work Load Manager. Minimum length = 1
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: 1
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Session
The NetScaler session. If omitted, the current default session is used.
Type: PSObject
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False
-IgnoreNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ReturnNullOnNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ThrowOnWarning
Treats NITRO warning responses as terminating errors.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-PassThru
Returns the updated resource after the operation completes.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSCustomObject
NOTES
Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.