Invoke-NSUnsetGSLBServiceGroup
Module area: NetScalerToolkit
Synopsis
Generated command reference. Review the command syntax and parameter metadata before use.
Syntax
Invoke-NSUnsetGSLBServiceGroup -ServiceGroupName <String> [-AppFlowLog <SwitchParameter>] [-CIP <SwitchParameter>] [-CIPHeader <SwitchParameter>] [-CltTimeout <SwitchParameter>] [-Comment <SwitchParameter>] [-DownStateFlush <SwitchParameter>] [-DupWeight <SwitchParameter>] [-HashID <SwitchParameter>] [-HealthMonitor <SwitchParameter>] [-MaxBandwidth <SwitchParameter>] [-MaxClient <SwitchParameter>] [-MonitorNameSvc <SwitchParameter>] [-MonThreshold <SwitchParameter>] [-Order <SwitchParameter>] [-Port <SwitchParameter>] [-Publicip <SwitchParameter>] [-PublicPort <SwitchParameter>] [-ServerName <SwitchParameter>] [-SitePersistence <SwitchParameter>] [-Siteprefix <SwitchParameter>] [-SvrTimeout <SwitchParameter>] [-Weight <SwitchParameter>] [-Session <PSObject>] [-IgnoreNotFound <SwitchParameter>] [-ReturnNullOnNotFound <SwitchParameter>] [-ThrowOnWarning <SwitchParameter>] [-PassThru <SwitchParameter>]
Parameters
-AppFlowLog
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-CIP
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-CIPHeader
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-CltTimeout
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-Comment
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-Confirm
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False - Aliases:
cf
-DownStateFlush
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-DupWeight
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-HashID
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-HealthMonitor
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-IgnoreNotFound
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-MaxBandwidth
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-MaxClient
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-MonitorNameSvc
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-MonThreshold
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-Order
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-PassThru
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-Port
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-Publicip
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-PublicPort
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-ReturnNullOnNotFound
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-ServerName
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-ServiceGroupName
- Type:
System.String - Required:
True - Pipeline input:
False
-Session
- Type:
System.Management.Automation.PSObject - Required:
False - Pipeline input:
False
-SitePersistence
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-Siteprefix
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-SvrTimeout
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-ThrowOnWarning
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-Weight
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False
-WhatIf
- Type:
System.Management.Automation.SwitchParameter - Required:
False - Pipeline input:
False - Aliases:
wi
Notes
This page was generated from exported PowerShell command metadata.