Invoke-NSUnsetAAARADIUSParams
SYNOPSIS
Clears one or more NetScaler aaaradiusparams resource properties.
SYNTAX
Invoke-NSUnsetAAARADIUSParams [-AccountIng] [-Authentication] [-Authservretry] [-AuthTimeout]
[-Callingstationid] [-DefaultAuthenticationGroup] [-IpattributeType] [-Ipvendorid] [-MessageAuthenticator]
[-Passencoding] [-PwdattributeType] [-Pwdvendorid] [-RadattributeType] [-RadGroupSeparator] [-RadGroupSprefix]
[-Radnasid] [-RadnaSIP] [-Radvendorid] [-ServerIp] [-ServerPort] [-TunnelendpointClientIp]
[[-Session] <PSObject>] [-IgnoreNotFound] [-ReturnNullOnNotFound] [-ThrowOnWarning] [-PassThru] [-WhatIf]
[-Confirm] [<CommonParameters>]
DESCRIPTION
Configuration for RADIUS parameter resource.
EXAMPLES
EXAMPLE 1
EXAMPLE 2
PARAMETERS
-AccountIng
Configure the RADIUS server state to accept or refuse accounting messages. Possible values = ON, OFF
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Authentication
Configure the RADIUS server state to accept or refuse authentication messages. Default value: ON Possible values = ON, OFF
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Authservretry
Number of retry by the Citrix ADC before getting response from the RADIUS server. Default value: 3 Minimum value = 1 Maximum value = 10
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-AuthTimeout
Maximum number of seconds that the Citrix ADC waits for a response from the RADIUS server. Default value: 3 Minimum value = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Callingstationid
Send Calling-Station-ID of the client to the RADIUS server. IP Address of the client is sent as its Calling-Station-ID. Default value: DISABLED Possible values = ENABLED, DISABLED
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-DefaultAuthenticationGroup
This is the default group that is chosen when the authentication succeeds in addition to extracted groups. Maximum length = 64
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-IpattributeType
IP attribute type in the RADIUS response. Minimum value = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Ipvendorid
Vendor ID attribute in the RADIUS response. If the attribute is not vendor-encoded, it is set to 0.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-MessageAuthenticator
Control whether the Message-Authenticator attribute is included in a RADIUS Access-Request packet. Default value: ON Possible values = ON, OFF
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Passencoding
Enable password encoding in RADIUS packets that the Citrix ADC sends to the RADIUS server. Default value: mschapv2 Possible values = pap, chap, mschapv1, mschapv2
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-PwdattributeType
Attribute type of the Vendor ID in the RADIUS response. Minimum value = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Pwdvendorid
Vendor ID of the password in the RADIUS response. Used to extract the user password. Minimum value = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-RadattributeType
Attribute type for RADIUS group extraction. Minimum value = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-RadGroupSeparator
Group separator string that delimits group names within a RADIUS attribute for RADIUS group extraction.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-RadGroupSprefix
Prefix string that precedes group names within a RADIUS attribute for RADIUS group extraction.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Radnasid
Send the Network Access Server ID (NASID) for your Citrix ADC to the RADIUS server as the nasid part of the Radius protocol.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-RadnaSIP
Send the Citrix ADC IP (NSIP) address to the RADIUS server as the Network Access Server IP (NASIP) part of the Radius protocol. Possible values = ENABLED, DISABLED
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Radvendorid
Vendor ID for RADIUS group extraction. Minimum value = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ServerIp
IP address of your RADIUS server. Minimum length = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ServerPort
Port number on which the RADIUS server listens for connections. Default value: 1812 Minimum value = 1
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-TunnelendpointClientIp
Send Tunnel Endpoint Client IP address to the RADIUS server. Default value: DISABLED Possible values = ENABLED, DISABLED
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Session
The NetScaler session. If omitted, the current default session is used.
Type: PSObject
Parameter Sets: (All)
Aliases:
Required: False
Position: 1
Default value: (Get-NSSession)
Accept pipeline input: False
Accept wildcard characters: False
-IgnoreNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ReturnNullOnNotFound
Returns null instead of throwing for known NITRO not-found responses.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-ThrowOnWarning
Treats NITRO warning responses as terminating errors.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-PassThru
Returns the updated resource after the operation completes.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
System.Management.Automation.PSCustomObject
NOTES
Generated from NetScaler NITRO API metadata. Generated: 2026-06-01 21:28 Supported metadata versions: 13.1, 14.1.